OREAS 80 has been characterized using the following methods:
Lithium borate fusion with X-ray fluorescence
Full ICP-OES and ICP-MS elemental suites by 4-acid (HNO3-HF-HClO4-HCl)
digestion
Sodium peroxide fusion or lithium borate fusion with full ICP-OES and
ICP-MS suites
Sulphur by infrared combustion furnace
Certified values for applicable analytes are operationally defined for each
method, with results under OREAS ISO 17034 scope of
accreditation.
Specifications
- State: primary
- Matrix: mineralised ultramafic
- Mineralisation: komatiite-hosted nickel sulphide
- CRM Group: Ni sulphide ore
Certified Values
| Analyte | Certified Value | 1SD | 95% CL Low | 95% CL High | Method |
|---|---|---|---|---|---|
| Ni, Nickel (wt.%) | 0.240 | TBD | TBD | TBD | 4-Acid Digestion |
| Cu, Copper (ppm) | 55 | TBD | TBD | TBD | 4-Acid Digestion |
| Cr, Chromium (wt.%) | 0.120 | TBD | TBD | TBD | 4-Acid Digestion |
| S, Sulphur (wt.%) | 0.310 | TBD | TBD | TBD | Infrared Combustion |
| Co, Cobalt (ppm) | 92 | TBD | TBD | TBD | 4-Acid Digestion |
Product Specifications
Certified Reference Values
| Analyte | Certified Value | Uncertainty (1SD) | 95% Confidence Low | 95% Confidence High | Method |
|---|
SD = Standard Deviation | CL = 95% Confidence Limits
Methods: AR = Aqua Regia, 4-Acid = 4-Acid Digestion, LBF = Lithium Borate Fusion, FA/AAS = Fire Assay with Atomic Absorption, LECO = LECO Combustion Analysis